NOVASFER / NOVABOX serie 300 / Mod. 310

BIOMASS

Biomass Circulation Groups

BIOMASS HEATING CIRCULATION

Mod. 310 - NOVABOX serie 300

Hydraulic separation unit with heating and sanitary management with tank, without primary pump

Cod.19912340

Novabox mod.300 has the following functions:

• Energy transfer from a biomass generator

• Energy exchange between generator and heating circuit

• Hydraulic separation between generator and the heating circuit

• Management of the integrated circuit on a sanitary tank

• Other functions

The unit conforms to ISPESL document dated 18/09/2006

 

Read more
Watch the video of NOVABOX serie 300

The Product

ISPESL document dated 18/09/2006 regarding thermal plants with two heat generators, one of which fed through solid fuel and the other with a different fuel says that: “In case the primary thermal fluid of two generators goes directly into the thermal tank, the sum of powers has to be considered; hence in case power is above 35 kW, the plant must be included in the M.D. 1/12/1975 and following norm updates. If instead there is a heat exchanger between the two generators, it can be considered as an hydraulic interruption between the two thermal fluids and therefore there is no need to sum the powers”.

The hydraulic separation units NOVABOX mod. 310, thanks to their hydraulic layouts, comply with ISPESL document in addition to managing the heating circuit and a coil for fresh water instant production with tank, have high level performances. The pumps, GRUNDFOS model UPM3 Hybrid, are high efficiency. There is the possibility to have up to 7 meter head pumps and the curves can be set with:

• Proportional pressure (default)

• Constant pressure

• Constant curves

A simple and complete installation is enabled thanks to hydraulic accessories which are supplied as standard:

• Valves

• Check valves

• Air vents

• Safety valves

• Temperature sensor

The hydraulic units can be supplied in metal boxes, to be wall-hung or to be built-in, painted.